NOTICE:  Surface  temperatures  of  adjacent 
walls and mantels become hot during opera-
tion. Walls and mantels above the firebox may 
become hot to the touch. If installed properly, 
these temperatures meet the requirement of the 
national product standard. Follow all minimum 
clearances shown in this manual.
NOTICE: If your installation does not meet the 
minimum clearances shown, you must do one 
of the following: 
•  operate the logs only with the flue damper 
open
•  raise the mantel to an acceptable height
•  remove the mantel
Figure 4 - Minimum Mantel Clearances Without Using Hood
14"
Min.
Combustible 
Material 
Noncombustible Material 
Figure 6 - Minimum Fireplace Clearances If Installed at 
Floor Level
Figure 5 - Minimum Mantel Clearances When Using Hood
Minimum Non- 
Combustible  
Material  
Minimum Non- 
Combustible  
Material Height  
Distances to  
Underside of 
Mantel  
Top of Fireplace 
Opening 
Underside of 
Mantel Shelf 
12"
(A) 
18"
20"
22"
24"
All minimum  
distances are 
in inches 
1/2
6" 
8" 
10" 
Mantel Shelf 
Minimum
Noncombustible 
Material 
8"
Min.
12"
15" 18" 20"
1/2
"
6"
8"
10"
12"
Distances to 
Underside of
Mantel 
Hood (GA6050
or GA6053)
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
 
Hearth
5"
Min.
Combustible 
Material 
Figure 7 - Minimum Fireplace Clearances Above 
Combustible Flooring
INSTALLATION
Continued
Determining Minimum Mantel Clearance When Using a 
Hood
If minimum clearances in Figure 4, are not met, you must have 
a hood. When using a hood there are still certain minimum 
mantel  clearances  required.  Follow  minimum  clearances 
shown in Figure 5, when using hood.
INSTALLING DAMPER CLAMP ACCESSORY FOR 
VENTED OPERATION
Note: When used as a vented indoor appliance, appliance 
must be installed only in a solid-fuel burning fireplace with a 
working flue and constructed of noncombustible material.
For Massachusetts Residents Only: Installation of this gas 
log set as a vented indoor appliance in the Commonwealth of 
Massachusetts requires the damper be permanently removed 
or welded in the fully open position.
You must install the damper clamp accessory (to order, see 
Accessories, page 21). This will insure vented operation (see 
Figure 8). The damper clamp will keep damper open. Instal-
lation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you 
must provide. Attach damper clamp so the minimum perma-
nent flue opening will be maintained at all times.
FLOOR CLEARANCES
A.  If installing appliance on the floor level, you must maintain 
the minimum distance of 14" to combustibles (see Figure 
6).
B.  If combustible materials are less than 14" to the fireplace, 
you must install appliance at least 5" above the combustible 
flooring (see Figure 7).