Hoshizaki C-101BAH-DS User Manual

Page of 40
25
Fig. 30
Piping to approved drain. 
Leave a 2-inch (5-cm) vertical 
air gap between the end of the 
pipe and the drain.
2-inch (5-cm) 
air gap
Floor
Drain
Shut-Off Valve
Drain Valve
Water Supply Inlet 
1/2" FPT
Drain Outlet
1/2" FPT
Vented Tee Connection
Extend the vent at least 12" 
(30 cm) above the drain outlet.
Minimum 1/4" Nominal ID Copper Water Tubing or Equivalent
Minimum 1/2" Nominal ID Hard Pipe 
or Equivalent
Be sure there is sufficient extra 
water supply line and drain line 
for the appliance to be pulled 
out for service.
• For gravity drain installation, drain must have 1/4" fall per foot (2 cm per 1 m) on horizontal 
runs to get good flow. A vented tee connection is also required for proper flow. Extend the 
vent at least 12" (30 cm) above the drain outlet.
• For optional drain pump installation, refer to the instructions included with the pump.