set service-profile web-portal-logout logout-url
475
set service-profile 
web-portal-logout 
logout-url
Specifies the URL that is requested when the user clicks the button to 
terminate his or her session in the Mobility Domain. 
Syntax — 
set service-profile
 
profile-name
 
web-portal-logout 
logout-url url
„
name
 — Service profile name.
„
url
 — Specifies the URL for the Web Portal logout feature. The URL 
should be of the form https://host/logout.html.
Defaults
 — 
By default, the logout URL uses the IP address of the WX as 
the 
host part of the URL. The host can be either an IP address or a 
hostname.
Access
 — 
Enabled.
History
 —
 Introduced in MSS Version 6.0.
Usage
 — 
Specifying the URL for the Web Portal logout feature is useful 
if you 
want to standardize the URL across your network. For example, 
you can configure the logout URL on all of the WX switches in the 
Mobility Domain as wifizone.3Com.com/logout.html, where 
wifizone.3Com.com resolves to one of the WX switches in the Mobility 
Domain, ideally the seed.
To log out of the network, the user can click the “End Session” button in 
the pop-under window, or request the logout URL directly.
Standardizing the logout URL serves as a backup means for the user to 
log out in case the pop-under window is closed inadvertently. Note that if 
a user requests the logout URL, he or she must enter a username and 
password in order to identify the session on the WX. (This is not necessary 
when the user clicks the “End Session” button in the pop-under 
window.) Both the username and password are required to identify the 
session. If there is more than one session with the same username, then 
requesting the logout URL does not end any session.