3com 6.0.4.6 User Manual

Page of 30
20
W
IRELESS
 LAN S
WITCH
 
AND
 C
ONTROLLER
 MSS V
ERSION
 6.0.4.6 R
ELEASE
 N
OTES
Known Problems
System Configuration Issues
Adding a static VLAN with the same name as a 
VLAN whose traffic is being tunneled through 
the switch can cause the switch to restart. 
(18367)
MSS can tunnel traffic for a VLAN through a WX 
switch that does not have that VLAN statically config-
ured. If you attempt to add a static VLAN to a switch 
that is already tunneling traffic for a VLAN with the 
same name, the switch can restart.
To create the VLAN, clear the Mobility Domain config-
uration from the switch, create the VLAN, and then 
configure the Mobility Domain again. 
The default value for RADIUS “deadtime” shown 
in the CLI help is incorrect. (41689)
The correct default value is 0.
When upgrading systems with large 
configurations, it may be necessary to save the 
configuration to a backup file. (41330)
When upgrading systems with very large configura-
tions, for example, hundreds of APs or hundreds of 
users, it may be necessary to save the configuration to 
a backup file, generate a minimal configuration, per-
form the update, load the backup configuration from 
the command line, and then save the configuration.
Time and date do not synchronize with an NTP 
server, if the switch's NTP client is enabled 
before the NTP service is started on the server. 
(20382)
Using set ap <apnum> boot configuration 
commands. (38517)
The set ap <apnum> boot-configuration switch 
switch-ip
 cannot be set at the same time as set ap 
<apnum> boot-configuration switch name 
<switch-name> dns <ip addr>
. The commands 
overwrite each other when used.
The auto-config feature does not work properly 
if the 3WXM server is unreachable when the 
auto-config feature is enabled. (44477)
To work around this issue, be sure that the 3WXM 
server is reachable from the wireless switch before 
you enable auto-config. If auto-config is enabled by 
default on the wireless switch, be sure that the 
3WXM server is reachable before you boot the wire-
less switch. 
Active AAA sessions (clients trying to 
establish active connections) per WX 
switch
WX4400: 2500
WX2200: 3200
WX1200: 300
WXR100: 75
These are the suggested maximums. 
The switch might be able to support 
even more sessions, but performance 
or system stability might be affected.
AAA users configured in local data-
base
WX4400: 999
WX2200: 999
WX1200: 250
WXR100: 250
Client and Session Parameter
Supported Value