3com WX2200 3CRWX220095A User Manual

Page of 750
set arp agingtime
169
set arp agingtime
Changes the aging timeout for dynamic ARP entries.
Syntax — 
set arp agingtime seconds
„
seconds
 — Number of seconds an entry can remain unused before 
MSS removes the entry. You can specify from 0 through 1,000,000. To 
disable aging, specify 0.
Defaults — None.
Access — Enabled.
History— Introduced in MSS Version 3.0.
Usage — Aging applies only to dynamic entries. 
To reset the ARP aging timeout to its default value, use the set arp 
agingtime 1200
 command.
Examples — The following command changes the ARP aging timeout to 
1800 seconds:
WX1200# set arp agingtime 1800
success: set arp aging time to 1800 seconds
The following command disables ARP aging:
WX1200# set arp agingtime 0
success: set arp aging time to 0 seconds
See Also
„
„