3com WX2200 3CRWX220095A User Manual

Page of 750
206
C
HAPTER
 7: IP S
ERVICES
 C
OMMANDS
Examples — To set the time zone for Pacific Standard Time (PST), type 
the following command:
WX1200# set timezone PST -8
Timezone is set to 'PST', offset from UTC is -8:0 hours.
See Also
„
„
„
„
„
„
„
telnet
Opens a Telnet client session with a remote device.
Syntax — 
telnet {ip-addr | hostname} [port port-num]
„
ip-addr
 — IP address of the remote device.
„
hostname
 — Hostname of the remote device.
„
port
 
port-num
 — TCP port number on which the TCP server on the 
remote device listens for Telnet connections. 
Defaults — MSS attempts to establish Telnet connections with TCP port 
23 by default.
Access — Enabled.
History —Introduced in MSS Version 3.0.
Usage — To end a Telnet session from the remote device, press Ctrl+t or 
type quit or logout in the management session on the remote device. To 
end a client session from the local WX switch, use the clear sessions 
telnet client
 command.
If the configuration of the WX switch from which you enter the telnet 
command has an ACL that denies Telnet client traffic, the ACL also denies 
access by the telnet command.