3com WX2200 3CRWX220095A User Manual

Page of 750
test
737
    3Com WX-4400 Bootstrap/Bootloader
                  Version  3.0.2  Release
    Compiled on Wed Sep 22 09:18:47 PDT 2004 by
     Bootstrap 0 version:           3.1     Active
    Bootloader 0 version:         3.0.2     Active
     Bootstrap 1 version:           3.1
    Bootloader 1 version:         3.0.1
       WX-4400 Board Revision:    2.
  WX-4400 Controller Revision:    5.
WXA30001.Rel 8863722 
bytes
    BOOT Index:   0
    BOOT TYPE:    c
    DEVICE:       boot0:
    FILENAME:     default
    FLAGS:        00000000
    OPTIONS:      run=nos;root=md0a
See Also
„
test
Displays or changes the state of the poweron test flag. The poweron test 
flag controls whether a WX performs a set of self tests prior to the boot 
process.
Syntax —
 test [ON | on | OFF | off]
„
ON
 — Enables the poweron test flag.
„
on
 — Same effect as ON.
„
OFF
 — Disables the poweron test flag.
„
off
 — Same effect as OFF.
Defaults — The poweron test flag is disabled by default.
Access — Boot prompt.
History —Introduced in MSS Version 3.0.