Alert 4015 
MCU <mcu> voice port capacity changed from <oldcapacity> to <newcapacity>.
The voice port capacity of the specified MCU has changed.
This could indicate a license change, video / voice port configuration change, or hardware change for the 
MCU (perhaps a media card has been added or removed). This alert appears as soon as the voice port 
capacity of this MCU becomes 0, and is automatically cleared after two minutes.
Click the link to go to the Network > MCU > MCUs page.
See also:
Alert 4016
MCU <mcu> has been automatically busied out due to <N> consecutive failures to start 
conferences. Investigate the MCU state and logs.
The specified MCU has been automatically busied out because it failed to start <N> number of conferences 
in a row. This condition is likely caused by an MCU software issue. Non-consecutive failures to start calls 
do not trigger this condition.
Once the MCU is busied out, when the last conference ends on the MCU, the MCU automatically changes 
to the Out of Service state. Once that happens, this alert is replaced with 
.
Click the link to go to the Network > MCU > MCUs page.
See also:
Alert 4017
MCU <mcu> has been automatically placed out of service due to <N> consecutive failures 
to start conferences. Investigate the MCU state and logs.
The specified MCU has been placed in the Out of Service state after it was automatically busied out because 
it failed to start <N> number of conferences in a row. This condition is likely caused by an MCU software 
issue.
This alert replaces 
.
Click the link to go to the Network > MCU > MCUs page.