2-1. Preparations
Equipment Required
. Electric Load
Hewlett-Packard
HP6051A 
+ HP60501B
. DC Voltmeter
Connection
Section 2
Electrical Alignment
2-2. Output Voltage Adjustment
Preparation
. Set the electric load to  9 A in the CC (constant current)
mode.
Test Points :
Pins (
+), (_)/5P terminal
Adj. Point :
1VR251 (SUB02 board)
Specifications : 16.7 
±0.3 V
SUB02 board (B side)
2-3. Note after Adjustment
After adjustment has been completed, be sure to lock
1VR251 with paint.
<Connection for 5P terminal>
Lower cover
To
DC Voltmeter
(
+)
(
_)
To
Electric Load
1
VR251