Mitsubishi Electronics FX3G User Manual
912
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
Series
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-2 Peripheral product applicability (except programming tools)
FX
3G
/FX
3GC
PLCs
FX
3U
/FX
3UC
PLC
*1.
The F940GOT and ET-940 whose version is earlier than Ver. 1.10 do not support the transparent (2-port)
function of the GX Developer.
function of the GX Developer.
Product Name
Applicability
Remarks
GOT1000 Series
Applicable
Standard monitor OS, communication driver and option OS which support the FX
3G
/FX
3GC
PLCs are required.
For details, refer to the GOT manual.
For details, refer to the GOT manual.
This series is subject to the following restrictions when connected using unsupported
standard monitor OS, communication driver or option OS.
standard monitor OS, communication driver or option OS.
Contents of restrictions
•
•
Programming is enabled only in the function ranges such as instructions, device ranges
and program sizes available in the FX
and program sizes available in the FX
1N
and FX
1NC
PLCs.
•
The list editor function for MELSEC-FX is not available. When using the list editor
function for MELSEC-FX, upgrade the standard monitor OS, communication driver and
option OS to the version compatible with the FX
function for MELSEC-FX, upgrade the standard monitor OS, communication driver and
option OS to the version compatible with the FX
3G
PLC.
Check the applicability of other items in the GOT manual.
F940WGOT
Not applicable
The following restriction applies when connected.
Contents of restrictions
Programming is enabled only in the function ranges such as instructions, device ranges and
program sizes available in the FX
Programming is enabled only in the function ranges such as instructions, device ranges and
program sizes available in the FX
1N
and FX
1NC
PLCs.
For applicable models, refer to the GOT manual.
For connection using the 2-port interface function
For connection using the 2-port interface function
*1
, refer to Appendix A-1-4.
F940GOT,
F940 Handy GOT
F940 Handy GOT
Not applicable
F930GOT (-K)
Not applicable
F920GOT (-K)
Not applicable
ET-940
Not applicable
FX-10DM (-SET0)
Not applicable
The following restriction applies when connected.
Contents of restrictions
Programming is enabled only in the function ranges such as instructions, device
ranges and program sizes available in the FX
Programming is enabled only in the function ranges such as instructions, device
ranges and program sizes available in the FX
1N
and FX
1NC
PLCs.
For supported models and device ranges, refer to the FX-10DM USER’ MANUAL
(Manual No. JY992D86401).
(Manual No. JY992D86401).
FX-10DU
Not applicable
The following restriction applies when connected.
Contents of restrictions
It is limited to the device range and function range supported by the highest class model
(FX
It is limited to the device range and function range supported by the highest class model
(FX
1N
or FX
1NC
) applicable in the product version.
For supported models and device ranges, refer to the FX-10DU Operation Manual
(Manual No. JY992D34701).
(Manual No. JY992D34701).
Product Name
Applicability
Remarks
GOT1000 Series
Applicable
(From first product)
The GOT1000 Series is applicable to the device ranges in the FX
3U
/FX
3UC
PLCs.
Check the applicability of other items in the GOT manual.
F940WGOT
Not applicable
The following restriction applies when connected.
Contents of restrictions
Programming is enabled only in the function ranges such as instructions, device ranges and
program sizes available in the FX
Programming is enabled only in the function ranges such as instructions, device ranges and
program sizes available in the FX
2N
and FX
2NC
PLCs.
For applicable models, refer to the GOT manual.
For connection using the 2-port interface function
For connection using the 2-port interface function
*1
, refer to Appendix A-1-4.
F940GOT,
F940 Handy GOT
F940 Handy GOT
Not applicable
F930GOT (-K)
Not applicable
F920GOT (-K)
Not applicable
ET-940
Not applicable
FX-10DM (-SET0)
Not applicable
The following restriction applies when connected.
Contents of restrictions
Programming is enabled only in the function ranges such as instructions, device ranges and
program sizes available in the FX
Programming is enabled only in the function ranges such as instructions, device ranges and
program sizes available in the FX
2N
and FX
2NC
PLCs.
For supported models and device ranges, refer to the FX-10DM USER’S MANUAL
(Manual No. JY992D86401).
(Manual No. JY992D86401).
FX-10DU
Not applicable
The following restriction applies when connected.
Contents of restrictions
It is limited to the device range and function range supported by the highest class model
(FX
It is limited to the device range and function range supported by the highest class model
(FX
2N
or FX
2
) applicable in the product version.
For supported models and device ranges, refer to the FX-10DU Operation Manual
(Manual No. JY992D34701).
(Manual No. JY992D34701).