Bit 10 to 8 — Cycle Count Maximum (CMAX): Indicates the maximum number of CCR. The 
number of basic cycles available in the matrix cycle for Timer Triggered transmission is (Cycle 
Count Maximum + 1). 
Unless CMAX = 3'b111, this module is in time-trigger mode and time trigger function is 
available. If CMAX = 3'b111, this module is in event-trigger mode. 
Bit[10:8]: CMAX[2:0] 
Description 
0 0 0 
Cycle Count Maximum = 0 
0 0 1 
Cycle Count Maximum = 1 
0 1 0 
Cycle Count Maximum = 3 
0 1 1 
Cycle Count Maximum = 7 
1 0 0 
Cycle Count Maximum = 15 
1 0 1 
Cycle Count Maximum = 31 
1 1 0 
Cycle Count Maximum = 63 
1 1 1 
CCR is cleared and this module is in event-trigger mode. (initial value) 
 
Important: Please set CMAX = 3'b111 when event-trigger mode is used. 
Bits 7 to 4: Reserved. The written value should always be '0' and the returned value is ‘0’. 
Bit 3 to 0 — Tx-Enable Window (TEW): Indicates the width of Tx-Enable Window. TEW = 
H'00 shows the width is one nominal Bit Timing. All values from 0 to 15 are allowed to be set. 
Bit[3:0]: TEW[3:0] 
Description 
0 0 0 0 
The width of Tx-Enable Window = 1 (initial value) 
0 0 0 1 
The width of Tx-Enable Window = 2 
0 0 1 0 
The width of Tx-Enable Window = 3 
0 0 1 1 
The width of Tx-Enable Window = 4 
. . . . 
. . . . . . 
. . . . 
. . . . . . 
1 1 1 1 
The width of Tx-Enable Window = 16 
Note:  The CAN core always needs a time between 1 to 2 bit timing to initiate transmission. The 
above values are not considering this accuracy.