Section 20   Controller Area Network 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1055 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
  Halt mode 
When this module is in Halt mode, it cannot take part to the CAN bus activity. Consequently the 
user can modify all the requested registers without influencing existing traffic on the CAN Bus. It 
is important for this that the user waits for this module to be in halt mode before to modify the 
requested registers  - note that the transition to Halt Mode is not always immediate (transition will 
occurs when the CAN Bus is idle or in intermission). After this module transit to Halt Mode, 
GSR4 is set. 
Once the configuration is completed the Halt request needs to be released. This module will join 
CAN Bus activity after the detection of 11 recessive bits on the CAN Bus. 
  Sleep mode 
When this module is in sleep mode the clock for the main blocks of the IP is stopped in order to 
reduce power consumption. Only the following user registers are clocked and can be accessed: 
MCR, GSR, IRR and IMR. Interrupt related to transmission (TXACK and ABACK) and reception 
(RXPR and RFPR) cannot be cleared when in sleep mode (as TXACK, ABACK, RXPR and 
RFPR are not accessible) and must to be cleared beforehand.