Section 25   NAND Flash Memory Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1331 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(3)  Flash Memory Access in Sector Access Mode 
Figures 25.13 and 25.14 show the timing of writing to and reading from the NAND-type flash 
memory in sector access mode. 
Figure 25.13 shows the timing of writing to the 1-Gbit large-block flash memory. During the 
execution of sequential sector access spanning multiple pages, data are written to the flash 
memory with the timing shown in the figure for every page (2048 + 64 bytes). 
CE
CLE
80h
10h
70h
Status read
1
2
M-1
M
CA
CA
PA
PA
(0-7) (8-11) (0-7) (8-15)
WE
ALE
RE
IO
R/B
M: 2112-th data 
 
Figure 25.13   Programming Operation Timing for NAND-Type Flash Memory