Renesas SH7264 User Manual

Page of 2152
 
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 452 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Table 11.13  TIOR_1 (Channel 1) 
    
Description 
Bit 7 
IOB3 
Bit 6 
IOB2 
Bit 5 
IOB1 
Bit 4 
IOB0 
TGRB_1 
Function 
 
TIOC1B Pin Function 
0 0 0 0 Output 
compare 
register 
Output retained* 
 
 
 
Initial output is 0 
0 output at compare match 
 
 
 
Initial output is 0 
1 output at compare match 
 
 
 
 
Initial output is 0 
Toggle output at compare match 
  1 0 0  
Output 
retained 
 
 
 
 
Initial output is 1 
0 output at compare match 
 
 
 
Initial output is 1 
1 output at compare match 
 
 
 
 
Initial output is 1 
Toggle output at compare match 
1 0 0 0 Input 
capture 
register 
Input capture at rising edge 
 
 
 
Input capture at falling edge 
 
 
Input capture at both edges 
 1 
 
Input 
capture 
at 
generation of TGRC_0 compare 
match/input capture 
[Legend] 
X: Don't 
care 
Note:  *  After power-on reset, 0 is output until TIOR is set.