Motorola MTM5400 User Manual
40
MTM5400 Mobile Terminal Installation Manual
INSTALLATION
Remote Mount Installation
Figure 10 Remote Mount Installation with Remote Head Enhanced/Data Expansion Head Enhanced
Table 4 Associated Components for Remote Mount
Item
Description
Part Number
1
Remote Mount Cable, 3 m
RKN4077
2
Remote Mount Cable, 5 m
RKN4078
3
Remote Mount Cable, 7 m
RKN4079
4
Remote Mount Cable, 10 m
PMKN4020
5
Remote Head Enhanced
PMLN4904
6
Data Expansion Head Enhanced
PMLN4908
Enhancement
7
Toroid EMC Suppression Kit
01015001001
When toroids are used on the Remote Mount Cable, wind
10 times around each toroid.
10 times around each toroid.
Each toroid have to be placed 30.0±2.5 cm respectively
from the expansion head and the control head.
from the expansion head and the control head.
Winding at both ends reduces the effective cable length
approximately by 0.8 m. Fix the toroids firmly to a stable
surface once the Remote Mount Cable is connected.
approximately by 0.8 m. Fix the toroids firmly to a stable
surface once the Remote Mount Cable is connected.
Transceiver
10-Pin
Connector
Remote Mount Cable
Remote Mount Enhanced
10-Pin
Connector
Remote Head
or
Data Expansion
Head Enhanced
Enhanced
Control Head