Chamberlain HS670 User Manual

Page of 36
24
GL BOARD FEATURES
DIAGNOSTICS (LEDS AND CODES)
There are three diagnostic LEDs. Two red LEDs (OL, CL) are
indicators for the open and close limits. The LEDs are illuminated
when the limit switch contacts are closed.
The third amber LED (DIA) is used to blink out diagnostic codes.
The number is the count of the number of times the LED is on in
an 8 second period. The LED is on for approximately 1/2 second
and repeats every second until the number is reached. There will
be a pause following each pulse cycle (1-6 pulses) to differentiate
between the different diagnostic codes.
Force Control
Max
Min
LED Code
Diagnostic Meaning
Cleared By
Flashed
OFF
Normal operation
N/A
1
Single entrapment sensed
Control Input
2
Double entrapment
Hard Input*
3
Failed or no hall effect sensor
Removal of problem
4
Exceed maximum motor run time
Hard Input*
5
Limit fault
Control Input
6
Loss of communications between master and second during run mode
Removal of problem
On No Flash
Motor not learned
Completion of Motor Learn Routine
*Hard inputs include open override, close override and stop inputs.
T R O U B L E S H O O T I N G
LED
LED NAME
DESCRIPTION
RELAY DRIVE TROUBLESHOOTING LEDS
There are 5 troubleshooting LEDs on relay drives K1 through K5. These
LEDs will be illuminated when the microcontroller relay drive is activated.
D6
Contactor A
On when Contactor A is activated
D5
Contactor B
On when Contactor B is activated
D4
SAM
On when SAM relay is activated
D3
Lock
On when Mag Lock relay is activated
D2
Alarm
On when Alarm Relay is activated
TROUBLESHOOTING LEDS
There are 9 troubleshooting LEDs.
LED
LED NAME
DESCRIPTION
D11
Radio
On when Radio switch is activated
D13
Shadow
On when Shadow Loop is activated
D15
Hard Close
On when Close switch is activated
D17
Stop
On when Stop switch is not activated
D19
Soft Open
On when Open switch is activated
D21
Hard Open
On when Open switch is activated
D24
Interrupt Loop
On when Interrupt/Safety Loop activated
D29
Obstruction Open
On when Edge is activated or when Photo Eye 
Beam is broken
D31
Obstruction Close
On when Edge is activated or when Photo Eye 
Beam is broken