Board Actuator 
Function 
  
Cable 
 
Pin 1  Orange  
Open Limit 
Pin 2  White   
Close Limit 
Pin 3  Black   
Motor (positive on open, negative on close) 
Pin 4  Red 
 
Motor (negative on open, positive on close) 
Pin 5  Green   
Common for both limit switches 
Pin 6  Yellow   
Feedback from intelligent actuator (816E/816EX) 
Pin 7  Black   
Battery Negative 
Pin 8  Red 
 
Battery Positive  
Actuator Connector  
 
 
 
Applies battery voltage directly to motor to open gate if    
 
 
control board fails. User must unplug before gate opens   
 
 
to maximum travel or 15 amp fuse will open. Fuse  
 
 
 
should be checked before returning gate to service. 
EMERGENCY BYPASS (open only) 
Connects control board to a computer using 
GateLink
 software. This software 
can monitor and diagnose the functions of the microprocessor. Ask your sales-
person about this feature. 
GateLink
 Connector 
12V 
Supplied battery voltage 
 
SLV 
Slave Operator Indicator (indicates slave side of gate is closed)  
 
+12V when on closed limit.    Ground when off of closed limit. 
MAS 
Master Operator Indicator (indicates master side of gate is closed) 
 
+12V when on closed limit.    Ground when off of closed limit. 
GND 
Battery supplied ground 
 
SIREN   Connect to siren +       
 
applies +12V when gate(s) are running, or in hard shutdown 
 
GND
 
Battery supplied ground 
 
LOCK  Connect to lock + (optional)   Magnetic or Solenoid type locks (Dip Switch #6 Selectable) 
Remote Outputs