GND 
Supplied Battery Ground 
 
INP 
Activate Gate (Push button activation when momentarily shorted to ground) 
 
12V 
Supplied Battery Voltage (Protected with 3 Amp fuse) 
GND 
Supplied Battery Ground 
 
INP 
Activate Gate (Push button activation when momentarily shorted to ground) 
 
12V 
Supplied Battery Voltage (Protected with 3 Amp fuse) 
EDGE  Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open. 
 
EDGE
  Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open. 
 
GND
 
Supplied Battery Ground 
 
GND 
Supplied Battery Ground 
 
STOP  Stop input from a 3 button station (must remove STOP CIRCUIT JUMPER) Normally closed 
 
CLOSE  Close input from a 3 button station (see program switch #5 for options)  
 
OPEN  Open input from a 3 button station (see program switch #5 for options) 
GND 
Supplied Battery Ground 
 
GND 
Supplied Battery Ground 
 
FREE EXIT      Opens gate if closed, stops and reverses gate if closing, resets close timer if gate is open. 
 
GND
 
Supplied Battery Ground 
 
SHADOW     Resets close timer when gate is open (also referred to as under gate loop) 
 
GND 
Supplied Battery Ground 
 
SAFETY     Resets close timer if gate is open, stops and reverses if gate is closing. (Does not open a closed gate)  
GND 
Supplied Battery Ground 
 
FIRE 
When grounded, opens gate and holds gate open until released.  
 
Clears “Hard Shutdown” mode of  software. 
UL 
When grounded, opens gate and holds gate open until released.  
 
Clears “Hard Shutdown” mode of  software. 
 
Optional Device Inputs 
GND 
Supplied Battery Ground 
 
INP 
Activate Gate (Push button activation when momentarily shorted to ground) 
 
12V 
Supplied Battery Voltage (Protected with 3 Amp fuse)