Troubleshooting the Filer Hardware
3-19
Parity disk x% rebuilt
The system shows the amount of com-
pleted data reconstruction on the spare 
disk after the system entered degraded 
mode. 
x—Amount of data reconstructed. If an 
error occurs during reconstruction, the 
error message overrides this message.
Power supply degraded!
One of the power supply units is down.
For more information about this error 
message, check the messages on the 
console. The power supply unit (1 or 2) 
generating the alarm is identified on the 
console message.
Replace NVRAM batteries!
This message appears in these situations:
An NVRAM card battery is low or dis-
charged. Replace both batteries as 
soon as possible.
Both batteries on the NVRAM card 
are low or discharged. The system 
will shut down every 24 hours to 
encourage you to replace the batter-
ies as soon as possible. To set the 
time that the system runs before it 
automatically shuts down, use the 
raid.timeout
 option with the 
options
 command. Refer to the Dell 
PowerVault 720N, 740N, and 760N 
System Administrator and Command 
Reference Guide 
 for more 
information.
Both NVRAM card batteries are low 
or discharged and the system is in 
degraded mode. The system shuts 
down immediately. 
/% - # :
-
$