Renesas R5S72622 User Manual

Page of 2152
 
Section 25   NAND Flash Memory Controller 
Page 1338 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
25.5
 
Interrupt Sources 
This module has seven interrupt sources: Status error, ready/busy timeout error, ECC error, 4-
symbol ECC pattern generation end, transfer end, FIFO0 transfer request, and FIFO1 transfer 
request. Each of the interrupt sources has its corresponding interrupt flag and the interrupt can be 
requested independently to the CPU if the interrupt is enabled by the interrupt enable bit. Note that 
the status error, ready/busy timeout error, ECC error, and 4-symbol ECC pattern generation end, 
use the common FLSTE interrupt to the CPU. 
Table 25.4  NAND Flash Memory Controller Interrupt Requests 
Interrupt Source 
Interrupt Flag 
Enable Bit 
Description 
Priority 
FLSTE interrupt 
STERB 
STERINTE Status 
error 
High 
BTOERB 
RBERINTE 
Ready/busy timeout error 
ECERB ECERINTE 
ECC 
error 
4ECCEND 
4ECEINTE 
4-symbol ECC pattern 
generation end 
FLTEND interrupt 
TREND 
TEINTE 
Transfer end 
FLTRQ0 interrupt  
TRREQF0 
TRINTE0 
FIFO0 transfer request 
FLTRQ1 interrupt 
TRREQF1 
TRINTE1 
FIFO1 transfer request 
Low 
 
25.6
 
DMA Transfer Specifications 
This module can request DMA transfers separately to the data area FLDTFIFO and control code 
area FLECFIFO. Table 25.5 summarizes DMA transfer enable or disable states in each access 
mode. 
Table 25.5  DMA Transfer Specifications 
 
Sector Access Mode 
Command Access Mode 
FLDTFIFO 
DMA transfer enabled 
DMA transfer enabled 
FLECFIFO 
DMA transfer enabled 
DMA transfer disabled 
 
For details on settings of the direct memory access controller, see section 10, Direct Memory 
Access Controller.