Renesas R5S72624 User Manual

Page of 2152
 
Section 21   IEBus
TM
 Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1127 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
21.3.18
  IEBus Receive Status Register (IERSR) 
IERSR detects receive busy, receive start, receive normal completion, or receive completion with 
an error. Each status flag in IERSR corresponds to a bit in the IEIER that enables/disables each 
interrupt. This register is cleared by writing 1 to each bit. 
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R/(W)
* R/(W)* R/(W)* R/(W)* R/(W)* R/(W)* R/(W)* R/(W)*
Bit:
Initial value:
R/W:
RXBSY
RXS
RXF
RXEDE RXEOVE
RXE 
RTME
RXEDLE
RXEPE
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
7 RXBSY 
R/(W)* Receive 
Busy 
Indicates that the receive data is stored in the receive 
data buffer (IERB001 to IERB128). Clear this bit after 
reading out all data. The next receive data cannot be 
received while this bit is set. 
[Setting condition] 
  When all receive data has been written to the 
receive data buffer. 
[Clearing condition] 
  When 1 is written 
6 RXS  0 
R/(W)* 
Receive Start Detection 
Indicates that this module starts reception. 
[Setting condition] 
  When the data from the master unit to message 
length field has been received correctly in slave 
reception 
[Clearing condition] 
  When 1 is written