Section 14   Realtime Clock 
 
 
Page 690 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
14.3.13
  Date Alarm Register (RDAYAR) 
RDAYAR is an alarm register corresponding to the BCD-coded date counter RDAYCNT. When 
the ENB bit is set to 1, a comparison with the RDAYCNT value is performed. From among 
RSECAR/RMINAR/RHRAR/RWKAR/RDAYAR/RMONAR/RCR3, the counter and alarm 
register comparison is performed only on those with ENB bits set to 1, and if each of those 
coincides, an alarm flag of RCR1 is set to 1. 
The assignable range is from 01 through 31 + ENB bits (practically in BCD), otherwise operation 
errors occur. 
Undefined
Undefined Undefined Undefined Undefined Undefined Undefined
R/W
ENB
0
1
2
3
4
5
6
7
R/W
R/W
R/W
0
R
BIt:
Initial value:
R/W:
-
10 days
R/W
R/W
R/W
1 day
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
ENB 
Undefined  R/W 
When this bit is set to 1, a comparison with the 
RDAYCNT value is performed. 
 0 R 
Reserved 
 
This bit is always read as 0. The write value should 
always be 0. 
5, 4 
10 days 
Undefined  R/W 
Ten's position of dates setting value 
3 to 0 
1 day 
Undefined  R/W 
One's position of dates setting value