Renesas R5S72624 User Manual

Page of 2152
 
Section 15   Serial Communication Interface with FIFO 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 769 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
  Transmitting and Receiving Serial Data Simultaneously (Clock Synchronous Mode) 
Figure 15.18 shows a sample flowchart for transmitting and receiving serial data 
simultaneously. 
Use the following procedure for the simultaneous transmission/reception of serial data, after 
enabling transmit/receive operation. 
Start of transmission and reception
Initialization
Read TDFE flag in SCFSR
TDFE = 1?
Write transmit data to SCFTDR, 
read TDFE and TEND flags 
in SCFSR as 1, 
and then clear the flags to 0
Read ORER flag in SCLSR
ORER = 1?
Read RDF flag in SCFSR
RDF = 1?
Clear TE and RE bits 
in SCSCR to 0
End of transmission and reception
Read receive data in
SCFRDR, and clear RDF
flag in SCFSR to 0
All data received?
No
No
Yes
No
No
Yes
Yes
[1] Status check and transmit data write:
     Read SCFSR and check that the 
TDFE flag is set to 1, then write 
transmit data to SCFTDR. Clear the 
TDFE and TEND flags to 0 after 
reading them as 1. The transition of 
the TDFE flag from 0 to 1 can also be 
identified by 
a transmit FIFO data 
empty interrupt (TXI).
[2]  Receive error handling:
      Read the ORER flag in SCLSR to 
identify any error, perform the 
appropriate error handling, then clear 
the ORER flag to 0. Reception cannot 
be resumed while the ORER flag is 
set to 1.
[3]  Status check and receive data read: 
      Read SCFSR and check that RDF 
flag = 1, then read the receive data in 
SCFRDR, and clear the RDF flag to 
0. The transition of the RDF flag from 
0 to 1 can also be identified by 
receive FIFO data full interrupt 
(RXI).
[4]  Serial transmission and reception 
continuation procedure:
     To continue serial transmission and 
reception, read 1 from the RDF flag 
and the receive data in SCFRDR, and  
clear the RDF flag to 0 before 
receiving the MSB in the current 
frame. Similarly, read 1 from the 
TDFE flag to confirm that writing is 
possible before transmitting the MSB 
in the current frame. Then write data 
to SCFTDR and clear the TDFE flag 
to 0. 
[1]
Yes
Error handling
[4]
When switching from a transmit operation 
or receive operation to simultaneous 
transmission and reception operations, 
clear the TE and RE bits to 0, and then 
set them simultaneously to 1.
Note:
[3]
[2]
 
Figure 15.18   Sample Flowchart for Transmitting/Receiving Serial Data