Section 16   Renesas Serial Peripheral Interface 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 807 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
16.3.15
  Buffer Data Count Setting Register (SPBFDR) 
SPBFDR indicates the number of data units stored in the transmit buffer (SPTX) and receive 
buffer (SPRX). The upper eight bits indicate the number of transmit data units in SPTX and the 
lower eight bits indicate the number of receive data units in SPRX. 
15
14
13
12
11
10
9
8
Bit:
Initial value:
R/W:
0
0
0
0
0
0
0
0
R
R
R
R
R
R
R
R
T[3:0]
7
6
5
4
3
2
1
0
Bit:
Initial value:
R/W:
0
0
0
0
0
0
0
0
R
R
R
R
R
R
R
R
R[5:0]
 
 
Bit Bit 
Name 
Initial 
Value 
R/W Description 
15 to 12 
 All 
Reserved 
The write value should always be 0. Otherwise, 
operation cannot be guaranteed. 
11 to 8 
T[3:0] 
0000 
R/W 
Indicates the number of bytes of data to be 
transmitted in SPTX. 
B'0000 indicates that SPTX is empty. 
B'1000 indicates that SPTX is full. 
7, 6 
 All 
Reserved 
The write value should always be 0. Otherwise, 
operation cannot be guaranteed. 
5 to 0 
R[5:0] 
000000 
R/W 
Shows the number of bytes of received data in 
SPTX. 
B'000000 indicates that SPRX is empty. 
B'100000 indicates that SPRX is full.