Renesas R5S72644 User Manual

Page of 2152
 
Section 21   IEBus
TM
 Controller 
Page 1106 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W  Description 
2 to 0 
CMD 
000 
Command 
These bits issue a command to control 
communications. When the CMX flag in IEFLG is set 
after the command issuance, the command is indicated 
to be in execution. When the CMX flag becomes 0, the 
operation state is entered. 
000: No operation. Operation is not affected. 
001: Unlock (required from other units)*
1
 
010: Requires communications as the master 
011: Stops master communications*
2
 
100: Undefined bits*
4
 
101: Requires data transfer from the slave 
110: Stops data transfer from the slave*
3
 
111: Undefined bits*
4
 
Notes:  1.  Do not execute this command in slave communications. 
 
2.  This command is valid during master communications (MRQ = 1). In other states, this 
command issuance is ignored. If this command is issued in master communications, the 
communications controller immediately enters the wait state. At this time, the issued 
master transmission request ends (MRQ = 0). 
 
3.  This command is valid during slave communications (SRQ = 1). In other states, this 
command issuance is ignored. Once this command is issued in slave transmission, the 
SRQ flag is 0 before slave transmission. Therefore, a transmit request from the master 
is not responded to. If a transmit request is issued during slave transmission, the 
transmission stops and the wait state is entered (SRQ = 0). 
 
4.  Undefined bits. Issuing this command does not affect operation.