Renesas R5S72621 User Manual

Page of 2152
 
Section 21   IEBus
TM
 Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1141 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
21.5.4
 
Master Reception 
Figure 21.11 shows the flowchart for master reception. 
START
END
[IEMCR register setting]
Broadcast/normal selection
Retransfer counts 
Control bits
Initial setting
[IESA1, IESA2 register setting]
Slave address
[IECMR register setting]
Master communications 
request command
Receive start interrupt
Receive error interrupt
(RXE***)
Receive start interrupt (RXS)
Interrupt processing
IERSR[RXS] clear
Receive completion 
interrupt
Receive error interrupt
(RXE***)
Receive completion interrupt (RXF)
Interrupt processing
IERSR[RXF] clear
Receive data read
(IERB001 to IERB128)
IERSR[RXBSY] clear
Interrupt processing
IETSR[TXE***] clear 
IERSR[RXE***] clear
 
Figure 21.11   Flowchart for Master Reception