Renesas R5S72621 User Manual

Page of 2152
 
Section 22   Renesas SPDIF Interface 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1189 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
22.10
  Disabling the Module 
22.10.1
  Transmitter and Receiver Idle 
The transmitter or receiver modules can be disabled by writing 0 to the idle bit in the control 
register (TME for the transmitter and RME for the receiver). The idle state can be detected by 
polling the idle bit in the status register (TIS and RIS). 
22.11
  Compressed Mode Data 
Compressed mode data is defined in the IEC 61937 specification. This module only detects 
compressed mode data. This is done by checking the parity flag (V flag) and bit 1 in the channel 
status data. If both are one then the data is in compressed mode. This is indicated by the setting of 
the CMD bit in the status register. 
Note:  Only the receiver detects compressed mode data since the information is not relevant to 
the transmitter. 
22.12
  References 
IEC60958 Digital Audio Interface 
IEC61937 Compressed Mode Digital Audio Interface