Section 33   Power-Down Modes 
Page 1786 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
33.2.8
 
Standby Control Register 8 (STBCR8) 
STBCR8 is an 8-bit readable/writable register that controls the operation of each module. 
Note:  When writing to this register, see section 33.4, Usage Notes. 
7
6
5
4
3
2
1
0
Bit:
Initial value:
R/W:
1
1
1
1
1
1
1
R/W
R
R
R
R
R
R/W
1
R
-
MSTP
87
-
-
-
MSTP
80
-
-
 
 
Bit Bit 
Name 
Initial 
Value R/W Description 
MSTP87 
R/W 
Module Stop 87 
When the MSTP87 bit is set to 1, the clock supply to 
the motor control PWM timer is halted. 
0: The motor control PWM timer runs. 
1: Clock supply to the motor control PWM timer is 
halted. 
6 to 1 

All 1 
Reserved 
These bits are always read as 1. The write value 
should always be 1. 
MSTP80 
R/W 
Module Stop 80 
When the MSTP80 bit is set to 1, the clock supply to 
the decompression unit is halted. 
0: The decompression unit runs. 