Section 34   User Debugging Interface 
Page 1824 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
34.4
 
Operation 
34.4.1
 
TAP Controller 
Figure 34.2 shows the internal states of the TAP controller. This state machine conforms to the 
state transitions defined by JTAG. 
Test -logic-reset
Capture-DR
Shift-DR
Exit1-DR
Pause-DR
Exit2-DR
Update-DR
Select-DR
Run-test/idle
1
0
0
0
0
1
1
1
1
0
0
0
1
1
1
0
1
1
1
0
Capture-IR
Shift-IR
Exit1-IR
Pause-IR
Exit2-IR
Update-IR
Select-IR
0
0
1
0
0
0
1
0
1
1
1
0
 
Figure 34.2   TAP Controller State Transitions 
Note:  The transition condition is the TMS value at the rising edge of TCK. The TDI value is 
sampled at the rising edge of TCK; shifting occurs at the falling edge of TCK. For details 
on transition timing of the TDO value, see section 34.4.3, TDO Output Timing. The TDO 
is at high impedance, except with shift-DR and shift-IR states. During the change to 
TRST 
= 0, there is a transition to test-logic-reset asynchronously with TCK.