Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 594 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
11.6.2
 
Interrupt Signal Timing 
(1)  TGF Flag Setting Timing in Case of Compare Match 
Figure 11.92 shows the timing for setting of the TGF flag in TSR on compare match, and TGI 
interrupt request signal timing. 
TGR
TCNT
TCNT input
clock
N
N
N + 1
Compare
match signal
TGF flag
TGI interrupt
P
φ
 