Section 14   Realtime Clock 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 685 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
14.3.8
 
Year Counter (RYRCNT) 
RYRCNT is used for setting/counting in the BCD-coded year section. The count operation is 
performed by a carry for each year of the month counter. 
The assignable range is from 0000 through 9999 (practically in BCD), otherwise operation errors 
occur. Carry out write processing after stopping the count operation through the setting of the 
START bit in RCR2. 
0
1
2
3
4
5
6
7
8
9
10
11
12
13
15
14
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
BIt:
Initial value:
R/W:
1000 years
100 years
10 years
1 year
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
15 to 12  1000 years  Undefined  R/W 
Counting Thousand's Position of Years 
11 to 8 
100 years
Undefined  R/W 
Counting Hundred's Position of Years 
7 to 4 
10 years 
Undefined  R/W 
Counting Ten's Position of Years 
3 to 0 
1 year 
Undefined  R/W 
Counting One's Position of Years