Renesas R5S72621 User Manual

Page of 2152
 
Section 14   Realtime Clock 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 691 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
14.3.14
  Month Alarm Register (RMONAR) 
RMONAR is an alarm register corresponding to the BCD-coded month counter RMONCNT. 
When the ENB bit is set to 1, a comparison with the RMONCNT value is performed. From among 
RSECAR/RMINAR/RHRAR/RWKAR/RDAYAR/RMONAR/RCR3, the counter and alarm 
register comparison is performed only on those with ENB bits set to 1, and if each of those 
coincides, an alarm flag of RCR1 is set to 1. 
The assignable range is from 01 through 12 + ENB bits (practically in BCD), otherwise operation 
errors occur. 
Undefined
Undefined Undefined Undefined Undefined Undefined
R/W
ENB
0
1
2
3
4
5
6
7
R/W
R/W
R/W
0
R
BIt:
Initial value:
R/W:
-
0
R
-
10 
months
R/W
R/W
1 month
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
ENB 
Undefined  R/W 
When this bit is set to 1, a comparison with the 
RMONCNT value is performed. 
6, 5 
 All 
Reserved 
These bits are always read as 0. The write value should 
always be 0. 
10 months 
Undefined  R/W 
Ten's position of months setting value 
3 to 0 
1 month 
Undefined  R/W 
One's position of months setting value