Renesas R5S72621 User Manual

Page of 2152
 
Section 15   Serial Communication Interface with FIFO 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 731 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Bit Bit 
Name 
Initial 
Value R/W Description 
0 DR  0 R/(W)* Receive Data Ready 
Indicates that the quantity of data in the receive FIFO 
data register (SCFRDR) is less than the specified 
receive trigger number, and that the next data has not 
yet been received after the elapse of 15 ETU from the 
last stop bit in asynchronous mode. In clock 
synchronous mode, this bit is not set to 1. 
0: Receiving is in progress, or no receive data 
remains in SCFRDR after receiving ended normally
[Clearing conditions] 
  DR is cleared to 0 when the chip undergoes a 
power-on reset 
  DR is cleared to 0 when all receive data are read 
after 1 is read from DR and then 0 is written. 
  DR is cleared to 0 when all receive data are read 
after the direct memory access controller is 
activated by receive FIFO data full interrupt (RXI).
1: Next receive data has not been received 
[Setting condition] 
  DR is set to 1 when SCFRDR contains less data 
than the specified receive trigger number, and the 
next data has not yet been received after the 
elapse of 15 ETU from the last stop bit.*
1
 
Note:  1.  This is equivalent to 1.5 frames with the 8-
bit, 1-stop-bit format. (ETU: elementary 
time unit)  
Note:  *  Only 0 can be written to clear the flag after 1 is read.