Renesas R5S72621 User Manual

Page of 2152
 
Section 18   Serial Sound Interface 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 929 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
18.4.3
 
Operation Modes 
There are three modes of operation: configuration, enabled and disabled. Figure 18.19 shows how 
the module enters each of these modes. 
TEN = 1 
or 
REN = 1 
(IDST = 0)
TEN = 0 
and 
REN = 0 
(IDST = 0) 
TEN = 0 
and 
REN = 0 
(IDST = 1)
Reset
Module 
configuration 
(after reset)
Module disabled 
(waiting until 
bus inactive)
Module enabled 
(normal tx/rx)
 
Figure 18.19   Operation Modes 
(1)  Configuration Mode 
This mode is entered after the module is released from reset. All required configuration fields in 
the control register should be defined in this mode, before this module is enabled by setting the 
TEN and REN bits. 
Setting the TEN and REN bits causes the module to enter the module enabled mode. 
(2)  Module Enabled Mode 
Operation of the module in this mode is dependent on the operation mode selected. For details, 
refer to section 18.4.4, Transmit Operation and section 18.4.5, Receive Operation, below.