Renesas SH7262 R5S72620 User Manual

Page of 2152
 
Section 28   Sampling Rate Converter 
Page 1648 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W  Description 
11 
UDEN 
R/W 
Output Data FIFO Underflow Interrupt Enable 
Enables/disables the output data FIFO underflow 
interrupt to be generated when output data FIFO is 
read and the UDF bit in SRCSTAT is set to 1 while 
the number of data units in the output data FIFO is 
zero. 
0: Disables output data FIFO underflow interrupt 
requests. 
1: Enables output data FIFO underflow interrupt 
requests. 
10 
OVEN 
R/W 
Output Data FIFO Overwrite Interrupt Enable 
Enables/disables the output data FIFO overwrite 
interrupt request to be issued when the conversion for 
the next data has been completed while the number 
of data units in the output FIFO is eight, thus setting 
the OVF bit in the status register (SRCSTAT) to 1. 
When OVEN = 1: Conversion processing is stopped 
until the OVF bit is cleared by the CPU accessing to 
SRCSTAT when the output data FIFO overwrite 
interrupt is generated. At this time, conversion result 
writing to the output data FIFO is also stopped. 
OVEN = 0: The OVF bit is automatically cleared when 
the output data FIFO has space, and conversion 
processing can be continued. 
0: Output data FIFO overwrite interrupt is disabled. 
1: Output data FIFO overwrite interrupt is enabled. 
FL 
R/W 
Internal Work Memory Flush 
Writing 1 to this bit starts converting the sampling rate 
of all the data in the input FIFO, input buffer memory, 
and intermediate memory (i.e., flush processing). This 
bit is always read as 0. When SRCEN = 0, writing 1 to 
this bit does not trigger flush processing. 
In addition, when 1 is written to the FL bit while the 
number of data units in the input buffer memory is 
less than the values shown in tables 28.9 and 28.10, 
valid output data cannot be received. Thus the 
internal work memory is cleared without triggering the 
flush processing.