SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W  Description 
3 to 0 
CTL*
1
 0000 
R/W 
Control 
Set the control bits in the control field for master 
transmission. 
0000: Reads slave status 
0001: Undefined*
3
 
0010: Undefined*
3
 
0011: Reads data and locks*
2
 
0100: Reads locked address (lower 8 bits) 
0101: Reads locked address (upper 4 bits) 
0110: Reads slave status and unlocks*
2
 
0111: Reads data 
1000: Undefined*
3
 
1001: Undefined*
3
 
1010: Writes command and locks*
2
 
1011: Writes data and locks*
2
 
1100: Undefined*
3
 
1101: Undefined*
3
 
1110: Writes command 
1111: Writes data 
Notes:  1.  CTL3 decides the data transfer direction of the message length bits in the message 
length field and data bits in the data field: 
 
 
CTL3 = 1: Transfer is from master unit to slave unit 
 
 
CTL3 = 0: Transfer is from slave unit to master unit 
 
2.  Control bits to lock and unlock 
 3. 
Setting 