Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 484 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W Description 
SYNC2 
R/W 
Timer Synchronous operation 2 to 0 
These bits are used to select whether operation is 
independent of or synchronized with other channels. 
When synchronous operation is selected, the TCNT 
synchronous presetting of multiple channels, and 
synchronous clearing by counter clearing on another 
channel, are possible. 
To set synchronous operation, the SYNC bits for at 
least two channels must be set to 1. To set 
synchronous clearing, in addition to the SYNC bit, the 
TCNT clearing source must also be set by means of 
bits CCLR0 to CCLR2 in TCR. 
0: TCNT_2 to TCNT_0 operates independently (TCNT 
presetting /clearing is unrelated to other channels) 
1: TCNT_2 to TCNT_0 performs synchronous operation 
TCNT synchronous presetting/synchronous clearing 
is possible 
1 SYNC1 0  R/W 
0 SYNC0 0  R/W