SH7262 Group, SH7264 Group
(2)  A/D Converter Activation by Compare Match between TCNT_0 and TGRE_0 
The A/D converter can be activated by generating A/D converter start request signal TRG0N 
when a compare match occurs between TCNT_0 and TGRE_0 in channel 0. 
When the TGFE flag in TSR2_0 is set to 1 by the occurrence of a compare match between 
TCNT_0 and TGRE_0 in channel 0 while the TTGE2 bit in TIER2_0 is set to 1, A/D converter 
start request TGR0N is issued to the A/D converter. If A/D converter start signal TGR0N from 
this module is selected as the trigger in the A/D converter, A/D conversion will start. 
(3)  A/D Converter Activation by A/D Converter Start Request Delaying Function 
The A/D converter can be activated by generating A/D converter start request signal TRG4AN or 
TRG4BN when the TCNT_4 count matches the TADCORA or TADCORB value if the UT4AE, 
DT4AE, UT4BE, or DT4BE bit in the A/D converter start request control register (TADCR) is set 
to 1. For details, refer to section 11.4.9, A/D Converter Start Request Delaying Function. 
A/D conversion will start if A/D converter start signal TRG4AN from this module is selected as 
the trigger in the A/D converter when TRG4AN is generated or if TRG4BN from this module is 
selected as the trigger in the A/D converter when TRG4BN is generated. 
Table 11.56  Interrupt Sources and A/D Converter Start Request Signals 
Target Registers 
Interrupt Source 
A/D Converter Start Request 
Signal 
TGRA_0 and TCNT_0 
Input capture/compare match 
TRGAN 
TGRA_1 and TCNT_1 
TGRA_2 and TCNT_2 
TGRA_3 and TCNT_3 
TGRA_4 and TCNT_4 
TCNT_4 
TCNT_4 Trough in 
complementary PWM mode 
TGRE_0 and TCNT_0 
Compare match 
TRG0N 
TADCORA and TCNT_4 
TRG4AN 
TADCORB and TCNT_4 
 
TRG4BN