Renesas R5S72647 User Manual

Page of 2152
 
Section 24   A/D Converter 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1285 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Sensor input
This LSI
Sensor output impedance
Low-pass filter
C to 0.1 
μF
Up to 5 k
Ω
Cin =
15 pF
20 pF
3 k
Ω
Note:  Values are reference values.
A/D converter 
equivalent circuit
 
Figure 24.10   Example of Analog Input Circuit 
24.7.6
 
Influences on Absolute Precision 
Adding capacitance results in coupling with GND, and therefore noise in GND may adversely 
affect absolute precision. Be sure to connect AVss, etc. to an electrically stable GND. 
Care is also required to insure that filter circuits mounted on the board do not pick up interference 
from digital signals (i.e., by acting as antennae). 
24.7.7
 
Note on Usage in Scan Mode and Multi Mode 
Starting conversion immediately after having stopped scan mode or multi mode operation may 
lead to erroneous results of conversion. 
To perform continuous conversion in such cases, set ADST to 0, wait for at least the A/D 
conversion time for a single channel to elapse, and then start conversion (ADST = 1). (The A/D 
conversion time for a single channel will vary according to the settings of the ADC registers.)