Yamaha Ro8-D User Manual

Page of 26
Controls and Functions
 Owner’s Manual
10
Controls and Functions
Front Panel
1
[INPUT] Connectors 1–8 (Ri8-D only)
These are the XLR-3-31 type analog balanced 
connectors for the input channels. The input level 
range is from –62 dBu to +10 dBu. +48V phantom 
power can be supplied to devices that require it via the 
input connectors.
NOTE
The PAD will be switched on or off internally when the gain 
of the internal head amp is adjusted between +17 dB and 
+18 dB. Keep in mind that noise may be generated if there 
is a difference between the Hot and Cold impedance of the 
external device connected to the INPUT connector when 
using phantom power.
2
OUTPUT +4 dBu Connectors 1–8 (Ro8-D only)
These XLR-3-32 type balanced connectors deliver 
analog output from the unit’s corresponding output 
channels. Nominal output level is +4 dBu.
3
[+48V] Indicators (Ri8-D only)
These indicators light when +48V phantom power is 
turned ON for the corresponding input channels. 
Phantom power supply switching can be carried out 
from a compatible digital mixing console or computer 
application. No phantom power will be supplied, 
however, if the [+48V MASTER] switch is OFF, even 
if phantom power to individual channels is turned ON 
(the +48V indicators will still light). The +48V 
indicators also function as error indicators: the 
indicators for all channels will flash if an error occurs.
CAUTION:
• Make sure that phantom power is turned OFF unless it is 
needed.
• When turning phantom power ON, make sure that no 
equipment other than phantom-powered devices such as 
condenser microphones are connected to the 
corresponding [INPUT] connectors. Applying phantom 
power to a device that does not require phantom power can 
damage the connected device.
• Do not connect or disconnect a device to an INPUT while 
phantom power is applied. Doing so can damage the 
connected device and/or the unit itself.
• To prevent possible damage to speakers, make sure that 
power amplifiers and/or powered speakers are turned OFF 
when switching phantom power ON or OFF. We also 
recommend setting all digital mixing console output 
controls to minimum when turning phantom power ON or 
OFF. Sudden high level peaks caused by the switching 
operation can damage equipment as well as the hearing of 
those present.
4
[PEAK] Indicators (Ri8-D only)
These indicators light red when the signal level of the 
corresponding channel reaches or exceeds –3 dBFS.
The PEAK indicators also function as error 
indicators: the indicators for all channels will flash if 
an error occurs.
5
[SIG] (Signal) Indicators
These indicators light green when the signal applied 
to the corresponding channel reaches or exceeds 
–34 dBFS.
The SIG indicators also function as error indicators: 
the indicators for all channels will flash if an error 
occurs.
6
[UNIT ID] Rotary Switch
This rotary switch enables you to set an ID number so 
that connected devices will recognize the 
Ri8-D/Ro8-D. The UNIT ID must be a unique 
number in the network so that the Ri8-D/Ro8-D will 
be able to transmit and receive audio signals over a 
Dante network, or be controlled from a connected 
digital mixing console.
Use the rotary switch while the power to the unit is 
turned OFF. Otherwise, the ID setting will not be 
effective.
7
[SYSTEM] Indicators
These indicators show the Ri8-D/Ro8-D’s operating 
status. If the green indicator lights steadily and the red 
indicator turns off, the unit is operating normally.
When power to the unit is turned ON, if the green 
indicator turns off, or if the red indicator lights or 
flashes, the unit is not functioning properly. In this 
case, refer to the “Messages” section (see page 18).
1
1  2  3  4  5  6  7  8
ON
1  2  3  4  5  6  7  8
ON
1
1
2
B
3
4
5
A
0
7
8
7 8
6
9