Tektronix AM700 User Manual

Page of 271
CALCulate Subsystem (FFT Analyzer)
AM700 Audio Measurement Set Programmer Manual
3–35
CALCulate Subsystem (FFT Analyzer)
Usage:
This is the CALCulate Subsystem for the FFT Analyzer. The CALCulate
subsystem performs post–acquisition data processing. Functions in the SENSe
subsystem are related to data acquisition, while CALCulate subsystem operates
on the data acquired by a SENSe function.
A number of independent subsystems comprise the CALCulate subsystem. Each of
the subsystems is a sub–block of the CALCulate block. Data flows through the
sub–blocks in serial fashion. The CALCulate block has more than one instance of
some of the sub–blocks. The same named sub–blocks are differentiated by a
numeric suffix.
Suffixes:
CALCulate1
Measurement Channel 1, Zoom
CALCulate2
Measurement Channel 1, Zoom
CALCulate3
Measurement Channel 1, Average
CALCulate4
Measurement Channel 1, Average
CALCulate[1–2]:FEED?
Usage:
Queries the data flow to the CALCulate block.
Query:
CALC1:FEED? 
returns 
”CSTM” 
and 
CALC2:FEED?
 returns 
”CSTR2”.
CALCulate[1–2]:TRANsform:FREQuency:STARt <numeric_value>
Usage:
Specifies the start frequency of FFT output.
Range:
Range and resolution are dependent on the input and sampling rate.
Input
Sampling Rate
Range (Hz)
Resolution (Hz)
High Res
48 kHz
0 to 19781.77
46.875
High BW
192 kHz
0 to 63975.09
187.06
AES
48 kHz
0 to 19781.77
46.875
44.1 kHz
0 to 18174.5
43.0644
32 kHz
0 to 13187.8
31.25