Gun Placement
3A2090A Operation
15
Gun Cable Adjustment
Adjusting the gun cable will increase or decrease the 
gap between the trigger plate and the gun trigger. To 
adjust trigger gap, perform the steps below.
1.
Use wrench to loosen locking nut on cable adjuster.
2.
Loosen or tighten adjuster until desired result is 
achieved. NOTE: More thread exposed means less 
gap between gun trigger and trigger plate.
3.
Use wrench to tighten locking nut on tie adjuster.
Adding Gun Cable 
1.
Install exposed cable through cable bracket slot.
2.
Insert plastic cable retainer into cable bracket hole. 
3.
Install cable end onto trigger plate pin and install 
clip. 
4.
Route cable around unit and up through cable holes 
behind hose mount.
5.
Route cable end loop through rectangular hole in 
bracket and insert plastic cable retainer into the 
actuator bracket. Install cable end onto actuator rod 
and install clip.
NOTE: Each gun actuator is capable of operating 
two cables. For second gun installation, attach cable 
to the unused actuator rod. 
+
ti18987a
ti18999a
ti18997a
ti18998a
ti19000a