Cleanup
3A2090A Operation
31
Cleanup
1.
Perform Pressure Relief Procedure, page 8.
2.
Remove guard and SwitchTip.
3.
Unscrew cap, remove filter. Assemble without filter. 
4.
Clean filter, guard and SwitchTip in flushing fluid.
5.
Place siphon tube set in grounded metal pail par-
tially filled with flushing fluid. Attach ground wire to 
true earth ground. Perform Startup steps 1 - 6 (see 
page 9) to flush out paint in sprayer. Use water to 
flush water-base paint and mineral spirits solvent 
(also called white spirit) to flush oil-base paint. 
6.
Hold gun against paint bucket and pull trigger until 
water or solvent appears. 
7.
Move gun to solvent or water bucket. Hold gun 
against bucket and pull trigger until the system is 
thoroughly flushed. 
8.
Fill pump with Pump Armor and reassemble filter, 
guard and SwitchTip. 
9.
Each time you spray and store, fill throat packing nut 
with TSL to decrease packing wear. 
This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing 
fluid and moving parts, follow the Pressure Relief 
Procedure when you stop spraying and before 
cleaning, checking, or servicing the equipment.