Yamaha HTR-6160 User Manual

Page of 144
34
 En
Optimizing the speaker setting for your listening room (YPAO)
7
Press 8n to select “START” and then press 
8
ENTER to start the setup procedure.
The following message appears in the OSD.
When this unit starts the automatic setup procedure, 
loud test tones are output at the speakers. 
For more accurate measurements, keep quiet and 
move to the wall where speakers are not around. We 
recommend that you leave the listening room during 
the automatic setup procedure.
Once you perform the next operation, this unit starts 
the automatic setup procedure.
8
Press 8
ENTER to start the automatic setup 
procedure.
The following screen appears in the OSD and setup 
procedure starts in 10 seconds.
Loud test tones are output from each speaker during 
the auto setup procedure. Once all items are set, the 
“RESULT” display appears in the OSD.
• During the automatic setup procedure, do not perform any 
operation on this unit.
• We recommend that you get out of the room while this unit 
is in the auto setup procedure. It takes approximately 3 
minutes for this unit to complete the auto setup procedure.
y
Press 8k to cancel the automatic setup procedure.
9
Make sure that the following screen appears 
and then press 
8
ENTER to display the 
result screen.
The results displayed under “RESULT” are as 
follows:
Number of speakers   
SP
Displays the number of speakers connected to this 
unit in the following order:
Front/Back/Subwoofer
Speaker distance   
DIST
Displays the speaker distance from the listening 
position in the following order:
Closest speaker distance/Farthest speaker distance
Speaker level   
LVL
Displays the speaker output level in the following 
order:
Lowest speaker output level/Highest speaker output 
level
• The signal output at the SUBWOOFER PRE OUT 2 jack 
is the same as the one output at the SUBWOOFER PRE 
OUT 1 jack. Therefore, even if you connect two 
subwoofers, the number of the connected subwoofer is 
indicated as “0.1”.
• If “E-10:INTERNAL ERROR” appears during the testing 
procedure, restart from step 4.
• If you selected other than “AUTO” in step 5, no test tones 
are output.
• If an error occurs during the “AUTO SETUP” procedure, 
the setup procedure is canceled and an error screen 
appears. For details, see “If an error screen appears” on 
page 36.
• When this unit detects potential problems during the 
“AUTO SETUP” procedure, “WARNING” and the 
number of warning messages appears in the above of 
“RESULT” (see page 36).
• Depending on the listening environment, “SWFR 
PHASE:REV” appears during the automatic procedure 
and “SUBWOOFER PHASE” in “SOUND MENU” (see 
page 87) is a
utomatically set to “REVERSE”.
Notes
NOTICE
output.
  
Loudtesttonesare
Pleasekeepquiet
orleavetheroom.
Press[ENTER]
AUTOSETUP
MeasurementStart
in 9seconds
[RETURN]:Cancel
Notes
AUTOSETUP
 RESULT
SP
:
3/4/0.1
DIST: 14.0/17.0ft
LVL : -9.0/+6.5dB
. SET CANCEL
[ ]/[ ]:Up/Down
[ENTER]:Enter
>
AUTOSETUP

Measurement Complete
Press [ENTER]