I.PLG FEEDBACK CONTROL
4. PLG FEEDBACK CONTROL
This function is used with a speed detector (PLG) to allow the motor speed to be detected by the speed detector and
fed back to the inverter so that the output frequency of the inverter is controlled to keep the motor speed constant to
load variations. Pr. 367 "speed feedback range" is factory-set to "9999" and Pr. 370 "control mode selection" to "0",
making this function invalid.
4.1. Wiring Example
(Note 4)
IM
PLG
5V
0
NFB
R (L1)
S (L2)
T (L3)
STF
STR
SD
U
V
W
FR-A5AP
PA1
PA2
PAR
PB1
PB2
PBR
5V
SG
C
R
A
N
H
K
10
2
5
E
Power supply
Forward rotation
Reverse rotation
Frequency setting 
potentiometer
Inverter
Standard motor with PLG (SF-JR)
(Note 1)
(Note 1)
5VDC 
power supply 
     
       (Note 2)
(Note 4)