Mitsubishi FR-A5AP User Manual

Page of 58
39
4.5. Related Parameter List
Control Mode
Parameter
Number
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
PLG feedback
control
Vector
control
22
Torque limit level (Stall prevention
operation level) (Note 1)
0 to 200%, 9999
0.1%
150%

 (Note 3)

29
Acceleration/deceleration pattern
0, 1, 2, 3, 4
1
0

(Note 4)

(Note 4)
144
Number of motor poles (Speed
setting switch-over) (Note 1)
0, 2, 4, 6, 8, 10,
102, 104, 106,
108, 110
1
4


162
Automatic restart after
instantaneous power failure
selection
0, 1, 2
1
0


285
Overspeed detection frequency
0 to 30Hz, 9999
0.01Hz
9999


359
PLG rotation direction
0, 1
1
1


367
Speed feedback range
0 to 400Hz,
9999
0.01Hz
9999


368
Feedback gain
0 to 100
0.1
1


369
Number of PLG pulses
0 to 4096
1
1024


370
Control mode selection
0, 1, 2
1
0


371
Torque characteristic selection
0, 1
1
1


372
Speed control P gain
0 to 200%
0.1%
100%


373
Speed control I gain
0 to 200%
0.1%
20%


374
Overspeed detection level
0 to 400Hz
0.01Hz
120Hz


375
Servo lock gain
0 to 150
1
20


380
Acceleration S pattern 1
0 to 50%
1%
0%


381
Deceleration S pattern 1
0 to 50%
1%
0%


382
Acceleration S pattern 2
0 to 50%
1%
0%


383
Deceleration S pattern 2
0 to 50%
1%
0%


Note: 1. When the FR-A5AP is not fitted, the function names in parentheses are used.
2. •  in the Control Mode field indicates that the corresponding function is valid.
3. Functions as the stall prevention operation level.
4. The acceleration/deceleration pattern C setting (Pr. 29 = 4) is made valid when the FR-A5AP is fitted.