American Water Heater (A)BCG385T500-8N User Manual

Page of 40
11
Servicing should only be performed by a Qualifi ed Service Agent
INSTALLATION CONSIDERATIONS
VENTING
The (A)BCG385T500-8N/8P water heater is classified by ANSI as a Category I (non-
condensing, negative pressure venting) appliance. It is approved for type B vent. The 
blower (draft inducer) does not pressurize the exhaust.
NOTE: This section of the service manual is not a complete venting installation instruction.  
Refer to the instruction manual that came with the water heater; ensure the venting has 
been installed per all instruction manual requirements.  Installation must also conform with  
the current edition of the National Fuel Gas Code (NFPA 54/ANSI Z223.1).  Costs to correct 
installation errors are not covered under the limited warranty. 
Figure 7
For larger applications, (A)BCG385T500-8N/8P water heaters can be common vented 
together, either in a tapered manifold or a constant size manifold.  See Figure 8.  In such 
cases, follow the National Fuel Gas Code requirements for the sizing and installation of fan-
assisted products.  The (A)BCG385T500-8N/8P model may be common vented only with 
other Category I appliances.
Figure 8