the remote port is located. The remote system must be located on the same 
FDDI ring as the system to which the analyzer is attached.
Figure 9-1 shows the process for establishing local and remote monitoring 
of ports.
Figure 9-1   Roving Analysis of Local and Remote Ethernet Ports
Configuration rules
You can have a maximum of 16 network analyzers connected to a system 
(the maximum number of Ethernet ports on a system) and up to 8 ports 
monitored per system. The network analyzer cannot be located on the same 
segment as the port you want to monitor. In general, you will configure one 
analyzer port ➊ and from there monitor one Ethernet port at a time ❷. 
Displaying the 
Roving Analysis 
Configuration
You can display the roving analysis configuration to see which ports are 
designated as analyzer ports and which ports are currently being monitored 
on a specific system.
When you display the roving analysis configurations for a system, you 
receive:
A list of analyzer ports on the system (ports connected to a network 
analyzer), including the Ethernet port number and the Ethernet MAC 
address of the port
A list of ports being monitored on the system, including the Ethernet port 
number and the Ethernet MAC address of the port to which the analyzer is 
attached