Rheem 82V120HE-T Leaflet

Page of 1
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117 • www.rheem.com
P R I N T E D I N U . S . A
0 6 / 0 8 W P
F O R M N O . 1 0 1 - 1 6 R e v. 1 3
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
HOT
COLD
VALVE
RELIEF
8"
B
WATER CONNECTION NIPPLES
ALL 3/4" N.P.T.
COLD
INLET
HOT
OUTLET
A
COLLECTOR
RETURN
COLLECTOR
FEED
WATER CIRCULATOR
(REQUIRED FOR NON-
GRAVITY SYSTEMS)
SO
LA
R E
NE
RG
Y
CO
LLE
CT
OR
SU
ITA
BL
E F
OR
PO
TA
BL
E W
AT
ER
AN
D P
RO
PY
LEN
E
GY
LC
OL
SO
LU
TIO
N
7"
DESCRIPTION
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFORMATION
ELEMENT
APPROX.
APPROX.
GAL.
WATTAGE
HEIGHT
DIAMETER
SHIP WT.
R-
CAP.
MODEL NUMBER
UPPER
A
B
(LBS.)
FACTOR
T
Y
P
E
80
81V80HE-1
4500 W*
58-3/4
24-1/2
222
R-17.3
80
81V80HE-T
Storage only
58-3/4
24-1/2
222
R-17.3
120
82V120HE-1
4500 W*
62
28-1/4
380
R-17.3
120
82V120HE-T
Storage only
62
28-1/4
380
R-17.3
Solaraide
HE
Solar Heat Exchanger, Solar Tank, or Electric Storage Water Heater
Available in 80 and 120 Gallon Models
6-Year Limited Tank and Parts Warranty*
Brass drain valve
Choice of two models…storage tank or
single element water heater specifically
engineered for installation with residential
indirect solar systems
Temperature and pressure relief valve included
Collector feed and return fittings located at
front of tank for convenient installation
Isolated tank design for better heat
retention
High efficiency heating element
Rheemglas
®
tank lining resists corrosion and
prolongs tank life
Heat exchanger: copper tubing wrapped
around and secured to the tank.
Double wall, vented design for positive
leak detection
Cold water inlet brings cold water to tank
bottom to prevent mixing with heated water
Anode rod equalizes aggressive water action
for prolonged tank life
Cold water inlet, hot water outlet, relief valve
and anode rod at top of tank for easy access
and fast, economical installation
Automatic temperature control
Over temperature protector
* See Residential Warranty Information Brochure
for complete warranty information.
* Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring and 4500 watt heating element.
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.
• To prevent corrosion, proper pH levels in transfer fluid must be maintained.
• Solaraide models meet all current state requirements for solar storage tanks.
• The tanks are Rheemglas lined and are designed to operate up to 150 PSI.
A special 1/2" NPT
opening 
is provided
for installation of a
“probe type”
thermostat.
COPPER COIL DATA (Type L Copper)
Maximum pressure = 150 PSI
Maximum temperature = 185° F
Tube I.D. = 5/8"
Solaraide HE
Coil Capacity
Length of Tubing
Tank Capacity
Gallons
Around Tank (Ft)
80 Gallons
2.2
120
120 Gallons
2.6
143
PRESSURE DROP THROUGH COIL (Feet of H
2
0)
Head Loss (Feet)
Flow Rate
80 Gallon
120 Gallon
1 GPM
1.3
1.6
2 GPM
4.8
5.7
3 GPM
10.0
12.0