Nilfisk Alto Centix 40 User Manual

Page of 49
16
CENTIX 60
english
Fault
Cause
Remedy
‡ Motor will not start
> Control cable disconnected
Check control cable (7) con-
nection to vacuum socket (10).
Check connection of 12V cont-
rol cable (7) coming from vacu-
um sockets to connector blocks 
(14) with connecting cable (16) 
to the CENTIX vacuum unit.
‡ Motor starts, but system 
does not operate at origi-
nal power
>
>
>
>
>
Vacuum sockets not sealed
Tube system damaged
Glued connections to suction 
tubes not tight
Test vacuum unit in mobile 
operation. If full suction power 
is available the tube system is 
blocked.
Vacuum unit not providing full 
suction power
Check alignment of vacuum 
socket and seals
Replace damaged tubes or 
elbows
Re-glue the suction tubes
See CENTIX operating instruc-
tions
Contact Alto customer service
5 Troubleshooting
Faults that affect the vacuum unit and its accessories are described in the CENTIX vacuum unit operating 
instructions.